Necessary conditions for the installation location of the package device

Answer technical service

study time 1 minute

Necessary conditions for the installation location of the package device

1. Size of the device's installation space:

The installation location of the device must have the necessary conditions for the chimney. The required space is one cubic meter per kilowatt of device power. If the volume of the installation place is less than the specified amount required by the device, the space where the device is installed should be connected to the adjacent room or free space, for this purpose, the top and bottom of the door of the room can be cut to the size of 5 cm and with Placing the mesh ventilators on the top and bottom of the door connected the installation location of the device to the adjacent room in a constantly open state. Read more: The most important points that must be followed in installing the wall package In order to connect the space where the device is installed to the adjacent room in a constantly open manner, mesh ventilators should be used at the top and bottom of the door.

If the space required to install the device is less than the allowed limit, it is necessary to connect the space where the device is installed to the adjacent room or open air, which must be open constantly. For example, windows that can be opened and closed or fans cannot be used because the window may be closed or the fan may be damaged. In this case, the device may supply the oxygen it needs from the room, which causes the people in that room to suffocate.

2. Oxygen Required of the device:

In addition to the fact that one cubic meter of space is needed for each kilowatt of power of the device, in order to prevent possible gas leakage and supply the device with oxygen from the outside environment, the room where the device is installed must also be open to the open air outside the room. Always keep the hatch or window open. Places where the device (wall package) should not be installed: Not installing a chimney device in places below 8 cubic meters Failure to install the device in places where there is a possibility of fire, such as storage of paper, thinner, paint and the like Failure to install devices in places where acid gases exist, such as above the washing machine, etc., which causes corrosion of the internal components of the device. If you have any doubts about the installation process of the wall package and the price of the parts of the Bhutan wall package, please let us know.

Places where the device (wall package) should not be installed:

Do not install a chimney device in places below 8 cubic meters Failure to install the device in places where there is a possibility of fire, such as storage of paper, thinner, paint and the like Not installing devices in places where there are acid gases, such as above the washing machine, etc., which causes corrosion of the internal components of the device.